Sigma -V series servo motor SGMSV.
Rated output: 4.0kw.
Power supply voltage: AC400V.
Serial encoder: 20 bit absolute value type (standard).
Design sequence: standard.
Shaft end: straight shaft with keyway, with screw (optional).
Optional: with hold brake (DC90V).
Super power rate.
Variety is complete (1.0kW ~ 7.0kW, with hold brake).
Equipped with a high resolution serial encoder (20 bit).
Standard using IP67 (7
SGMPS-01ACE6EE0kw for IP22).
Use example:
Placement machine.
Punch printed circuit board.
Machine tool feeding device.
Rating and specifications:
Rated time: continuous.
Vibration level: V15.
Insulation resistance: DC500V, 10M, or above.
Using ambient temperature: 0 ~ 40 degrees C.
Excitation mode: permanent magnet type.
Installation method: flange type.
Heat resistance grade: F.
Insulation withstand voltage: AC1500V 1 minutes (200V), AC1800V 1 minutes (400V).
Protection mode: fully enclosed self cooling type IP67 (except shaft through part).
The use of environmental humidity: 20 ~ 80% (not dew).
Connection mode: direct connection.
Rotation direction: clockwise direction (CCW) rotation at the load side under the direction of rotationServo motor type SGMAH (speed: 3000r\/min).
Power: 30W.
Power supply voltage: single phase AC200V.
Serial encoder: 13 bit relative value.
Design sequence: A.
Shaft end: straight shaft with screw key.
Optional parts: with oil seal, DC24V brake.
Improve mechanical properties.
In order to achieve a higher production efficiency, SGDMAH type to the best control to explore the highest performance of the machine,
Compared with the original models, CPU computing time for its 1\/2, through the expansion of the new control algorithm,
Positioning time is shortened to the original product of 1\/3, to achieve a good response.
The parameter setting and maintenance time is shortened.
In order to establish a high degree system in a short time, the use of the simplicity of the.
Flexible use of online automatic adjustment function,
Automatic adjustment of servo system with mechanical characteristics.
Then use the main loop \/ control circuit power separation and alarm tracking memory function, can be simple to carry out maintenance