Security module.
Maximum applicable motor capacity: 0.5kw.
Power supply voltage: three phase AC200V.
Interface: MECHATROLINK- III communication command type (rotary servo motor).
Design sequence: A.
Hardware specification: base mounting type (standard).
Matching (software): no matching (standard) SGDV-370D11A003FT003 USER'S MANUAL.
Matching (parameters): no matching (standard).
Optional module: security module
SGDV-370D11A003FT003
European EC standards: Based on the integration of mechanical instructions standard ISO13849-1 EN,
Security module with individual standard 61800-5-2 IEC specified security function.
Through the combination of the SGDV servo unit, the best safety design of the mechanical system is realized.
Suitable for AC servo drive, with the following safety features specified in the international standard IEC61800-5-2 (Japan''s first) SGDV-370D11A003FT003 USER'S MANUAL.
Can easily achieve the best security design of mechanical systems.
Torque Off Safe (STO)
Stop Safe 1 (SS1)
Stop Safe 2 (SS2)
Limited Speed Safely (SLS)
Equipped with 2 security functions, can be set (distribution) security functions.
In addition, the monitoring time and other items can be changed through the parameter SGDV-370D11A003FT003 USER'S MANUAL.
With the use of the servo unit with a security module, so that the system can be simplified and miniaturized. Security module.
Maximum applicable motor capacity: 1.0kw.
Power supply voltage: three phase AC400V.
Interface: MECHATROLINK- II communication command type (linear servo motor).
Design sequence: A.
Hardware specification: dynamic brake (DB).
Matching (software): no matching (standard).
Matching (parameters): no matching (standard).
Optional module: security module.
European EC standards: Based on the integration of mechanical instructions standard ISO13849-1 EN,
Security module with individual standard 61800-5-2 IEC specified security function.
Through the combination of the SGDV servo unit, the best safety design of the mechanical system is realized.
Suitable for AC servo drive, with the following safety features specified in the international standard IEC61800-5-2 (Japan''s first).
Can easily achieve the best security design of mechanical systems.
Torque Off Safe (STO)
Stop Safe 1 (SS1)
Stop Safe 2 (SS2)
Limited Speed Safely (SLS)
Equipped with 2 security functions, can be set (distribution) security functions SGDV-370D11A003FT003 Manual.
In addition, the monitoring time and other itemms can be changed through the parameter SGDV-370D11A003FT003 Manual.
With the use of the servo unit with a security module, so that the system can be simplified and miniaturized.